Reference ranges for cardiac dimensions and blood flow velocity in preterm infants

R. Skelton, Alan Gill, J M Parsons

Heart · 1998 · 41 citations · 10 references

DOIFull text

Open access

Concepts

Abstract

AIM: To establish reference ranges for cardiac dimensions and Doppler measurements in preterm infants. METHODS: 79 infants of less than 34 weeks' gestation were examined by echocardiography on days 0, 7, and 28 after birth, to produce a set of reference ranges and to examine changes in these indices over the first month of life. The following dimensions were measured: interventricular septum, left ventricular posterior wall, left interventricular diameter at end systole and diastole, left atrium, and aortic root; Doppler measurements were made of maximum blood flow velocity (Vmax) through the pulmonary, aortic, mitral, and tricuspid valves. RESULTS: Reference ranges are given. Cardiac dimensions correlated well with gestation and birth weight but Vmax did not. There was a significant increase in measurements over time. The "normal" preterm infant also appeared to often have asymmetrical septal hypertrophy. Antenatal dexamethasone administration did not appear to affect the measurements. CONCLUSIONS: There is a close correlation with both gestation and birth weight for all physical measurements. Echocardiograms in preterm babies clearly differ from those in older children and adults.