Radiology · 2010 · 58 citations · 8 references
MedicineBiomedical EngineeringRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyMagnetic Resonance ImagingMagnetic Resonance Imaging PhysicsMedical ImagingRadiofrequency ExcitationRadiographic ImagingSpine ImagingDiagnostic Quality MeasurementDiagnostic Quality MetricsImage Contrast EvaluationMagnetic ResonanceMagnetic Resonance Imaging AcquisitionMagnetic Resonance PhysicsParallel TransmissionSpecific Energy Absorption
PURPOSE: To prospectively and intraindividually compare single-source radiofrequency (RF) excitation and dual-source parallel RF excitation in 3.0-T magnetic resonance (MR) imaging of the spine. MATERIALS AND METHODS: Institutional review board approval and written informed patient consent were obtained. The RF power of a 3.0-T MR imaging system was distributed to two ports of the body coil of the system by using independent RF transmit channels. The maximum B(1) field strength for dual-source parallel RF excitation was maintained, as compared with single-source RF excitation. The repetition time was reduced according to the revised RF setup with dual-source parallel RF excitation while maintaining specific energy absorption limitations. Thirty patients were examined with and without dual-source parallel RF excitation. Diagnostic quality was assessed independently by two radiologists according to a four-point grading system. Image contrast ratios (CRs) were calculated between reference tissues and vertebrae for single-source RF excitation and dual-source parallel RF excitation. RESULTS: The mean acceleration achieved with dual-source parallel RF excitation was 36% (range, 18%-50%). The total imaging duration of a three-station total spinal examination was reduced by one-third by using dual-source parallel RF transmission. For all cases investigated, diagnostic image quality without significant differences between the two methods and with a good interobserver agreement was achieved (Kendall tau-b, 0.50-0.84). The observed image contrast changes were predominantly small (<0.10 in 15 of 24 CRs), though they were significantly different (P < .05). CONCLUSION: While shortening examination times by approximately one-third, the dual-source parallel RF transmission mode in MR imaging of the spine yielded diagnostic image quality comparable to that with the conventional single-source RF transmission mode.
8
SENSE: Sensitivity encoding for fast MRI
Klaas P. Pruessmann, Markus Weiger, Markus B. Scheidegger et al. · Magnetic Resonance in Medicine · 1999 · 6.1K citations
Ulrich Katscher, Peter Börnert, Christoph Leussler et al. · Magnetic Resonance in Medicine · 2002 · 703 citations · Full text