PubMed · 2001 · 130 citations · 22 references
Open access
MedicineNeurosurgeryRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyBrain ImagingMagnetic Resonance ImagingMagnetic Resonance Imaging PhysicsMedical ImagingNeurovascular ImagingSinus ImagingContrastContrast-enhanced Magnetic Resonance AngiographyFlow-related Signal ContrastMagnetic Resonance Flow ImagingSignal-to-noise RatioSignal-to-noise Ratio AnalysisSignal-to-noise Ratio EnhancementVenous Flow Dynamics
BACKGROUND AND PURPOSE: The diagnosis of dural sinus thrombosis is often difficult because of its variable and nonspecific clinical presentation and the overlapping signal intensities of thrombosis and venous flow on conventional MR images and MR venograms. We compared 3D contrast-enhanced magnetization-prepared rapid gradient-echo (MP-RAGE) sequences with 2D time-of-flight (TOF) MR venography, digital subtraction angiography (DSA), and conventional spin-echo (SE) MR imaging for the assessment of normal and abnormal dural sinuses. METHODS: In a phantom study, a plastic tube with pulsating flow was used to simulate the intracranial dural sinus. With 3D MP-RAGE, a variety of flow velocities, contrast material concentrations, and angulations between the phantom flow tube and the plane of acquisition were tested to measure their relationship to signal-to-noise ratio (SNR). In a clinical study, 35 patients, including 18 with suspected dural sinus thrombosis, were studied with both MR imaging and DSA. Receiver operating characteristic (ROC) analysis was performed in a blinded fashion using DSA as the reference standard. RESULTS: With the phantom, the SNR of flow increased with increasing contrast concentration, but was not affected by the angle between the tube and scan slab. There was no relationship between SNR and velocity when the contrast concentration was 1.0 mmol/L or greater. In the clinical study, dural sinus thrombosis as well as the normal anatomy of the dural sinuses were seen better with 3D contrast-enhanced MP-RAGE than with 2D-TOF MR venography. Three-dimensional contrast-enhanced MP-RAGE showed the highest diagnostic confidence on ROC curves in the diagnosis of thrombosis. CONCLUSION: Three-dimensional contrast-enhanced MP-RAGE is superior to 2D-TOF MR venography and conventional SE MR imaging in the depiction of normal venous structures and the diagnosis of dural sinus thrombosis, and is a potential alternative to DSA.
22
Cerebral MR venography: normal anatomy and potential diagnostic pitfalls.
R. H. Ayanzen, C R Bird, Paul J. Keller et al. · PubMed · 2000 · 440 citations · Full text
Medicine, Neurosurgery, Radiology +17
Cerebral venography: comparison of CT and MR projection venography.
R R Ozsvath, Sean O. Casey, Elizabeth S. Lustrin et al. · American Journal of Roentgenology · 1997 · 255 citations
Sean O. Casey, Ronald Alberico, Mahesh R. Patel et al. · Radiology · 1996 · 212 citations
Medicine, Neurosurgery, Radiology +17