Medicina oral, patología oral y cirugía bucal · 2012 · 13 citations · 31 references
DentistryDental Biomaterials ScienceDental Materials ScienceCavity PreparationDental MaterialsSurface Properties Of Dental MaterialsAdhesive DentistryDental AdhesivesDentin BondingAdhesive MaterialsAdhesivesCemento-dentinal JunctionHemostatic Agent UseMicrohybrid CompositesMicroleakage In RestorationsMicroleakage ReductionSelf-etching Adhesives
OBJECTIVE: This in vitro study evaluated the effect of Ankaferd Blood Stopper (ABS) contamination on the microleakage of one-step and two-step self-etching adhesives. STUDY DESIGN: Class V cavities were prepared at the cemento-enamel junction on both buccal and lingual surfaces of 60 freshly extracted human molars. Teeth were randomly assigned into three groups according to contamination material applied (Group I, no contamination; Group II, blood contamination; Group III, ABS contamination). In contaminated groups, one drop of blood and ABS solution was applied directly to the dentin surface and air-dried. Each group was further divided into two subgroups according to bonding agent used [Group A, Clearfil SE Bond (two-step self-etching adhesive); Group B, Adper Easy One (one-step self-etching adhesive)]. Adhesive materials were applied according to the manufacturers' recommendations. The specimens were restored using a universal microhybrid composite (Arabesk). After thermocycling (5000x, 5°C - 55°C) and immersion in a 0.5% basic fuchsin, dye penetration was evaluated under a stereomicroscope. Statistical analysis was performed with Kruskal-Wallis and Mann-Whitney U tests at p < 0.05. RESULTS: Significantly higher microleakage scores were observed when one-step self-etching adhesive was applied to blood- and ABS-contaminated dentin. However, when a two-step self etching adhesive was used, microleakage was observed only following blood contamination, not following ABS contamination. CONCLUSIONS: Although, blood contamination before adhesive application resulted in increased microleakage with both one-step and two-step self-etching adhesive systems, ABS contamination did not affect microleakage when a two-step self-ething adhesive system was used.
31
Jacques E. Nör · Operative Dentistry · 2006 · 586 citations · Full text
Haemostatic Actions of the Folkloric Medicinal Plant Extract Ankaferd Blood Stopper®
Hakan Göker, Sevil Ercetin, Ş Kirazlı et al. · Journal of International Medical Research · 2008 · 292 citations · Full text
Medicine, Botany, Hematology +17
Evaluation of hemostatic effects of Ankaferd as an alternative medicine.
Yavuz Beyazıt, Mevlüt Kurt, Murat Kekilli et al. · PubMed · 2010 · 98 citations
Medicine, Hematology, Pathology +15