Journal of Cardiovascular Electrophysiology · 2015 · 16 citations · 26 references
MedicineCardiologyPreventive CardiologyPulmonary Function TestingPulmonologyAntiarrhythmic TherapyAtrial FibrillationAutoantibodiesCardiac BiomarkersThrombosisAntiarrhythmic MedicationsAtrial Fibrillation BiomarkersEarly Recurrence PredictionPulmonary Vein Isolation
INTRODUCTION: Recent evidence has suggested that autoantibodies may play an important role in the development of atrial fibrillation (AF). The predictive value of preprocedural autoantibodies against beta-1 adrenergic receptor (anti-β1-R) and M2-muscarinic acetylcholine receptor (anti-M2-R) for AF recurrence following cryoballoon-based pulmonary vein isolation (PVI) is still unclear. We aimed to determine the predictive value of preprocedural anti-β1-R and anti-M2-R levels for AF recurrence. METHODS: Eighty patients (mean age 54.25 ± 7.70 years; 40% female) with paroxysmal AF and preserved left ventricular function who underwent cryoballoon-based PVI were included in the study. Preprocedural anti-M2-R and anti-β1-R levels were measured with ELISA. RESULTS: At 1-year follow-up after ablation, late AF recurrence was observed in 17 (21.25%) patients. In the Cox regression model, including number of antiarrhythmic drugs, early AF recurrence, anti-β1-R levels >159.88 ng/mL, anti-M2-R levels >277.65 ng/mL, AF duration, and left atrial volume index, only anti-β1-R levels >159.88 ng/mL (HR: 4.281, P = 0.039) and anti-M2-R levels >277.65 ng/mL (HR: 4.313, P = 0.030) were found to be independent predictors of late AF recurrence. Anti-β1-R level >159.88 ng/mL was shown to predict late AF recurrence with a sensitivity of 70.59% and specificity of 90.48%. A cut-off value of 277.65 ng/mL for anti-M2-R level predicted AF recurrence with a sensitivity of 70.59% and specificity of 95.24%. CONCLUSION: Preprocedural serum anti-β1-R and anti-M2-R levels are independent predictors of late AF recurrence following cryoballoon-based PVI in paroxysmal AF patients. Detection of preprocedural anti-β1-R and anti-M2-R levels may serve as a novel method for determination of paroxysmal AF patients who may not benefit from cryoballoon-based PVI.
26
2012 focused update of the ESC Guidelines for the management of atrial fibrillation
A. John Camm, Gregory Y.H. Lip, Raffaele De Caterina et al. · EP Europace · 2012 · 3.8K citations · Full text
Guidelines for the management of atrial fibrillation
A. John Camm, Paulus Kirchhof, Gregory Y.H. Lip et al. · EP Europace · 2010 · 1.7K citations · Full text
Hugh Calkins, Riccardo Cappato, Josép Brugada et al. · Heart Rhythm · 2012 · 1.5K citations · Full text
Medicine, Cardiology, Surgery +17