IEEE Transactions on Geoscience and Remote Sensing · 1990 · 82 citations · 8 references
Natural SciencesEarth SciencesMetrologyOcean InstrumentationRemote SensingCalibrationPhase AnalysisPolar Remote SensingRadar CalibrationRadar InstrumentationRadar Signal ProcessingInstrument Calibration For Polarimetric ImagingPhase CalibrationPolarimetric CalibrationPolarimetric Data ReductionPolarimetric Radar CalibrationRadar ImagingStokes ParametersSynthetic Aperture Radar
It is shown that the Stokes matrices measured by an imaging radar polarimeter provide enough information for the accurate phase calibration of the observed polarimetric characteristics of a surface. This is important because it allows the data to be reduced in volume in an operational synthetic aperture radar correlator with no prior knowledge of the conditions at the surface, and the end user can later select the particular region where he or she is comfortable with making an assumption regarding the relative phases of the hh and nu nu signals. No ground calibration equipment is necessary, as all important parameters are derived from the data themselves.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
8
Imaging radar polarization signatures: Theory and observation
J.J. van Zyl, H. A. Zebker, C. Elachi · Radio Science · 1987 · 554 citations
Polarization diversity in radars
Dino Giuli · Proceedings of the IEEE · 1986 · 402 citations