Equine Veterinary Journal · 1990 · 42 citations · 11 references
Health ProfessionsOphthalmologyVeterinary OphthalmologyEquine MedicineEquine ScienceOcular AnatomyEye ExaminationIntraocular Pressure MeasurementOcular BiometryMammalian Ocular Anatomy
Tonometric and tonographic techniques were evaluated in the normal pony and compared to other species. Applanation tonometry was utilised to calculate the ocular ridigity of the normal equine eye. The mean intraocular pressure for the pony eye was established as 23.5 mm Hg (sd +/- 4.5). Comparing the non-anaesthetised and anaesthetised pony eye (xylazine-ketamine and glycerol guaiacolate) no significant change in intraocular pressure occurred (P < 0.49). Mean aqueous outflow facility was 0.88 microliter/min/mm Hg (sd +/- 0.65) which is significantly higher (P < 0.01) than the canine and human species. The ocular rigidity values for the pony eye were higher which indicates that the eye is more rigid than either the canine or human eye.
11
Experimental Tonography in Rabbits
W. Kornblüth · A M A Archives of Ophthalmology · 1955 · 83 citations
Medicine, Ophthalmology, Surgery +12
Tonography in the normal and glaucomatous beagle.
Gelatt Kn, Gwin Rm, Peiffer Rl et al. · PubMed · 1977 · 32 citations