Soil Use and Management · 2004 · 33 citations · 8 references
AgricultureEarth SciencesSoil SciencesSoil PhysicsSoil ScienceSoil-water RelationsCalibrationMoisture DeterminationSoil DepthSoil MoistureSoil Sensor CalibrationWater ContentDielectric ConstantDielectric Constant MeasurementInstrumentation CalibrationSoil Moisture Measurement TechniquesSoil Moisture Sensor CalibrationSoil ProbesSoil Water Content CharacterizationSoil Water Measurement
Abstract. The in‐field calibration of a dielectric probe to measure soil water content is described. The probe uses an access tube analogous to that of the neutron probe. The dielectric constant was measured at soil depths of 10, 20, 30, 40, 60 and 100 cm. Cores of soil were then taken from the face of pits dug 30 cm from the access tube and their soil water contents determined by oven drying. The dielectric constant values measured by the probe were calibrated against water contents from these cores. We found that sensor depth needed to be included to achieve a good calibration model that explained 72% of the variance. It is argued that depth needs to be included because of artefacts introduced during the installation of the access tube.
8