European Heart Journal - Cardiovascular Imaging · 2013 · 62 citations · 21 references
MedicineBioengineeringCardiologyBiomedical ImagingHistologyHistopathologyCoronary Artery DiseaseCoronary Artery ImagingOptical Coherence TomographyPercutaneous Coronary InterventionStent PlacementTissue Optical PropertiesConnective Tissue DepositionCoronary Lesion AssessmentCoronary Stent RestenosisFibrin NetworksFibrous Tissue ArchitectureHistological TypingRestenosis After StentingTissue Morphology Analysis
AIMS: Although optical coherence tomography (OCT) is capable to detect microscopic peri-strut changes that seem to be related to neointimal inhibition and healing, its ability to characterize these components is still limited. In this study, we aimed to compare different OCT morphological characteristics with different in-stent neointimal tissue types analysed by histology. METHODS: A total of 69 stents (39 drug eluting and 30 bare metal stents) were implanted in coronary arteries of 27 swine. By OCT, neointimal type was classified as homogeneous, heterogeneous, or layered according to its pattern of backscatter and optical intensity. The resulting optical patterns were correlated with several histological findings [external elastic lamina (EEL) disruption, fibrin deposition, circumferential rim of peri-strut inflammatory cell infiltration, and fibrous connective deposition] in every single cross-section (CS) analysed. RESULTS: A total of 197 matched OCT and histological CS were analysed. The heterogeneous (0.44 ± 0.21 mm) and layered (0.65 ± 0.16 mm) patterns had a significantly higher degree of neointimal thickness compared with the homogeneous pattern (0.25 ± 0.16 mm, P < 0.001). Fibrous connective tissue deposition was more frequently present in the homogeneous pattern (71.6%, P < 0.001), whereas significant fibrin deposits were more commonly seen in the heterogeneous pattern (56.9%, P = 0.007). Peri-strut inflammation was less frequently found in the homogeneous pattern (19.8%, P < 0.001) in comparison with the layered (73.9%) or heterogeneous patterns (43.1%). The presence of EEL rupture was also more commonly seen in layered (73.9%) and heterogeneous (46.6%) patterns than in the homogeneous pattern (22.4%, P < 0.001). CONCLUSION: The optical characteristics of neointimal formation seen in OCT properly correlated with the presence of several histological findings involved in stent healing. The biological implications of these findings in clinical outcomes require further investigation.
21
A Polymer-Based, Paclitaxel-Eluting Stent in Patients with Coronary Artery Disease
Gregg W. Stone, Stephen G. Ellis, David A. Cox et al. · New England Journal of Medicine · 2004 · 2.7K citations · Full text
Medicine, Cardiology, Surgery +14
Pathology of Drug-Eluting Stents in Humans
Michael Joner, Aloke V. Finn, Andrew Farb et al. · Journal of the American College of Cardiology · 2006 · 2.7K citations
Medicine, Cardiology, Pathology +11
Pathological Correlates of Late Drug-Eluting Stent Thrombosis
Aloke V. Finn, Michael Joner, Gaku Nakazawa et al. · Circulation · 2007 · 1.3K citations · Full text
Characterization of Human Atherosclerosis by Optical Coherence Tomography
Hiroshi Yabushita, Brett E. Bouma, Stuart L. Houser et al. · Circulation · 2002 · 1.2K citations
Medicine, Bioengineering, Cardiology +17