EngineeringElectrical EngineeringElectric MachinesPower ElectronicsPropulsionDirect Current MachinesElectric MotorsElectromagnetic InductionInduction MachinesMotor Starting MethodsInduction Motor TheoryInduction MotorsMotor EfficiencyMotor Efficiency AnalysisPower FactorSquirrel Cage Motor StartingSquirrel-cage Induction MotorsStarting Current Limitation
Opportunities to improve motor efficiency by reducing the present restrictions on the motor starting current are identified. The existing National Electrical Manufacturer's Association (NEMA) standards are reviewed, and a new standard is recommended. The impact on motor operating temperature and power factor is discussed. In those cases where increased starting current is prohibitive, alternative starting methods are given.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
3