IEEE Transactions on Biomedical Engineering · 1994 · 36 citations · 7 references
Natural SciencesBiophysicsPhysiologyMedical PhysicsUltrasonographyUltrasoundAcoustic ScatteringHematocrit RegulationRed Blood Cell PhysiologyScattering TheoryUltrasonicsUltrasound PhysicsBackscatter CoefficientHematocrit Effects
The backscattering coefficient of saline suspensions of porcine red blood cells was measured for hematocrits up to about 90%. It was found that the coefficient peaks at approximately 15%, but then, contrary to what a simple "gap theory" might suggest, it decays smoothly to zero, without showing another peak at high hematocrits. A one-dimensional (1-D) slab scattering model, in which the number of slabs per unit length represents the hematocrit and whose thickness and acoustical properties are similar to red cells/plasma, was also used to investigate the relation between the backscattered power and hematocrit. Monte-Carlo simulations performed for randomized boundary conditions show a similar relation to that of the 3-D system. The experimental data is compared to the Percus-Yevick theory for the packing of hard spheres, and the simulated data is compared to the Percus-Yevick theory for infinite slabs.
7
Effect of flow disturbance on ultrasonic backscatter from blood
K. K. Shung, Y. W. Yuan, D. Y. Fei et al. · The Journal of the Acoustical Society of America · 1984 · 164 citations
Medicine, Physiology, Radiology +17