Circulation Arrhythmia and Electrophysiology · 2014 · 136 citations · 12 references
MedicineCardiologyCardiothoracic SurgeryInterventional CardiologyPulmonologyAblation TherapyCatheter AblationAblation TechnologyElectroporationElectroporation-based AblationHeart Size EnlargementPorcine ModelsRadiofrequency TreatmentSurgical AblationTissue Ablation
BACKGROUND: Radiofrequency ablation inside pulmonary vein (PV) ostia can cause PV stenosis. A novel alternative method of ablation is irreversible electroporation, but the long-term response of PVs to electroporation ablation is unknown. METHODS AND RESULTS: In ten 6-month-old pigs (60-75 kg), the response of PVs to circular electroporation and radiofrequency ablation was compared. Ten consecutive, nonarcing, electroporation applications of 200 J were delivered 5 to 10 mm inside 1 of the 2 main PVs, using a custom-deflectable, 18-mm circular decapolar catheter. Inside the other PV, circular radiofrequency ablation was performed using 30 W radiofrequency applications via an irrigated 4-mm ablation catheter. PV angiograms were made before ablation, immediately after ablation, and after 3-month survival. PV diameters and heart size were measured. With electroporation ablation, PV ostial diameter decreased 11±10% directly after ablation, but had increased 19±11% after 3 months. With radiofrequency ablation, PV ostial diameter decreased 23±15% directly after ablation and remained 7±17% smaller after 3 months compared with preablation diameter despite a 21±7% increase in heart size during aging from 6 to 9 months. CONCLUSIONS: In this porcine model, multiple circumferential 200-J electroporation applications inside the PV ostia do not affect PV diameter at 3-month follow-up. Radiofrequency ablation inside PV ostia causes considerable PV stenosis directly after ablation, which persists after 3 months.
12
Pulmonary Vein Stenosis After Radiofrequency Ablation of Atrial Fibrillation
Eduardo Saad, Antonio Rossillo, Cynthia P. Saad et al. · Circulation · 2003 · 355 citations · Full text
Medicine, Cardiology, Surgery +16
Small or Large Isolation Areas Around the Pulmonary Veins for the Treatment of Atrial Fibrillation?
Thomas Arentz, Reinhold Weber, Gerd Bürkle et al. · Circulation · 2007 · 353 citations
Medicine, Cardiology, Surgery +17
Pathological Effects of Extensive Radiofrequency Energy Applications in the Pulmonary Veins in Dogs
Gregg W. Taylor, G. Neal Kay, Xiangsheng Zheng et al. · Circulation · 2000 · 240 citations · Full text
Medicine, Cardiology, Surgery +15