Radiation Protection Dosimetry · 2009 · 20 citations · 24 references
MedicineNuclear EngineeringMedical PhysicsRadiation DosimetryRadiation PhysicsAbsorbed DoseEquivalent DoseMonte Carlo DosimetryRadiation Risk AssessmentRadiation TherapyTreatment Planning Dose CalculationClinical Photon Beam DosimetryEquivalent Dose DeterminationMonte Carlo Dose SimulationParticle Beam DosimetryPatient-specific Dose EstimationPhoton Dose CalculationRadiation Dose AssessmentRadiation Dose Estimation
This study of doses to patients from emitted photoneutrons in a medical linear accelerator (Varian 2100C) was carried out. Dose calculation was performed using Monte Carlo Geant4 code. The model was used to calculate the neutron fluence, as a function of the neutron energy inside the treatment room to estimate the effective dose to patients. The ambient dose equivalent versus field size for patients is reported in this study. The ambient dose equivalent using 1 x 1 cm(2) field size, at isocentre and X-ray modes of 20, 18, 15 and 10 MV, was found to be 1.85, 1.79, 0.61 and 0.06 mSv Gy(-1), respectively. The mean energies of emitted photoneutrons were 0.48, 0.44, 0.40 and 0.16 MeV at X-ray modes of 20, 18, 15 and 10 MV, respectively. The results of ambient dose equivalent from emitted photoneutrons cannot be ignored and can represent a risk for healthy tissues. This study emphasised that Geant4 Monte Carlo code is an appropriate choice for studying photoneutron production and transport.
24
Analysis of photoneutron spectra produced in medical accelerators
C. Ongaro, Alba Zanini, U. Nastasi et al. · Physics in Medicine and Biology · 2000 · 102 citations
Monte Carlo study of Siemens PRIMUS photoneutron production
J. Peña, L. Franco, F. Gómez et al. · Physics in Medicine and Biology · 2005 · 101 citations
Investigation of secondary neutron dose for dynamic MLC IMRT delivery
Rebecca M. Howell, Michele Ferenci, Nolan E. Hertel et al. · Medical Physics · 2005 · 84 citations · Full text