Journal of Cataract & Refractive Surgery · 2015 · 36 citations · 10 references
MedicineOphthalmologySurgeryClinical OptometryOphthalmic SurgeryRefractive SurgeryCataract ManagementGlaucomaGlaucoma SurgeryIntraocular Pressure MeasurementGlaucoma After Cataract SurgeryIntraocular Pressure Control After SurgeryIntraocular Pressure ElevationIntraocular Pressure ManagementIntraocular Pressure ReductionLaser Treatment Of GlaucomaPostoperative Intraocular Pressure MeasurementSurgical Outcomes In Glaucoma
PURPOSE: To compare changes in intraocular pressure (IOP) during femtosecond laser pretreatment of cataract between glaucomatous eyes and nonglaucomatous eyes. SETTING: Launceston Eye Institute and Launceston Eye Hospital, Launceston, Australia. DESIGN: Nonrandomized interventional prospective case series. METHODS: Patients with clinically stable primary open-angle glaucoma (POAG) having femtosecond laser pretreatment were compared with a concurrent cohort of patients with healthy eyes having the same procedure. Pretreatment was performed using a fluid-filled optical docking system (Liquid Optics Interface). With the patient supine, the IOP was measured at 4 time points using a rebound tonometer (Icare Pro). RESULTS: The study comprised 143 eyes of 97 patients. Forty-three eyes (30.1%) had documented glaucoma. The mean baseline IOP was 20.2 mm Hg ± 4.2 (SD) in glaucomatous eyes and 18.9 ± 4.0 mm Hg in nonglaucomatous eyes (P = .06). The mean change in IOP values between each time frame and baseline was as follows: vacuum-on, 13.8 ± 9.9 mm Hg and 11.1 ± 6.9 mm Hg, respectively (P = .06); after treatment, 17.4 ± 7.4 mm Hg and 14.1 ± 7.2 mm Hg, respectively (P = .014); after undocking of vacuum, 9.9 ± 5.4 mm Hg and 8.7 ± 5.7 mm Hg, respectively (P = .24). CONCLUSIONS: Femtosecond pretreatment caused a greater transient rise in IOP after treatment and a higher residual IOP after vacuum undocking in glaucomatous eyes than in nonglaucomatous eyes. This is well tolerated short term; however, long-term implications for eyes with glaucoma are unknown at present. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.
10
Complications of laser in situ keratomileusis for the correction of myopia
R. Doyle Stulting, Jonathan D. Carr, Keith P. Thompson et al. · Ophthalmology · 1999 · 497 citations
Medicine, Ophthalmology, Surgery +11
Optic neuropathy associated with laser in situ keratomileusis
Andrew G. Lee, Thomas Kohnen, Roberto Ebner et al. · Journal of Cataract & Refractive Surgery · 2000 · 104 citations
Medicine, Ophthalmology, Surgery +17
Laser in situ keratomileusis–induced optic neuropathy
Bruce D Cameron, Norman Saffra, Mitchell B. Strominger · Ophthalmology · 2001 · 104 citations
Medicine, Ophthalmology, Surgery +13
Intraocular pressure during phacoemulsification
Christopher Khng, Mark Packer, Howard I. Fine et al. · Journal of Cataract & Refractive Surgery · 2006 · 79 citations
Medicine, Ophthalmology, Surgery +14