Excluded AAAs can increase in size owing to persistent or recurrent pressurization (endotension) of the sac even when there is no evidence of endoleak. One proposed mechanism is pressure transmission via thrombus that lines the attachment site. Endotension may also represent an indiscernible, very low flow endoleak that allows blood to clot at the source of leakage.