Critical Care · 2010 · 39 citations · 35 references
MedicinePerioperative MedicineSurgeryCardiothoracic SurgeryHemodynamic ManagementPerioperative Outcomes ResearchAortic StenosisAortic Valve DiseaseCardiac Valve SurgeryCardiopulmonary BypassEchocardiographic Hemodynamic AssessmentLeft Ventricular Function AssessmentCardiac Systolic FunctionLeft Ventricular Diastolic DysfunctionLeft Ventricular Systolic FunctionPreoperative Cardiac EvaluationSystolic DysfunctionVentricular Diastolic FunctionVentricular Ejection Fraction AssessmentWeaning From Cardiopulmonary Bypass
INTRODUCTION: Left ventricular (LV) dysfunction frequently occurs after cardiac surgery, requiring inotropic treatment and/or mechanical circulatory support. In this study, we aimed to identify clinical, surgical and echocardiographic factors that are associated with LV dysfunction during weaning from cardiopulmonary bypass (CPB) in high-risk patients undergoing valve replacement for aortic stenosis. METHODS: Perioperative data were prospectively collected in 108 surgical candidates with an expected operative mortality >or=9%. All anesthetic and surgical techniques were standardized. Reduced LV systolic function was defined by an ejection fraction <40%. Diastolic function of the LV was assessed using standard Doppler-derived parameters, tissue Doppler Imaging (TDI) and transmitral flow propagation velocity (Vp). RESULTS: Doppler-derived pulmonary flow indices and TDI could not be obtained in 14 patients. In the remaining 94 patients, poor systolic LV was documented in 14% (n = 12) and diastolic dysfunction in 84% of patients (n = 89), all of whom had Vp <50 cm/s. During weaning from CPB, 38 patients (40%) required inotropic and/or mechanical circulatory support. By multivariate regression analysis, we identified three independent predictors of LV systolic dysfunction: age (Odds ratio [OR] = 1.11; 95% confidence interval (CI), 1.01 to 1.22), aortic clamping time (OR = 1.04; 95% CI, 1.00 to 1.08) and Vp (OR = 0.65; 95% CI, 0.52 to 0.81). Among echocardiographic measurements, Vp was found to be superior in terms of prognostic value and reliability. The best cut-off value for Vp to predict LV dysfunction was 40 cm/s (sensitivity of 72% and specificity 94%). Patients who experienced LV dysfunction presented higher in-hospital mortality (18.4% vs. 3.6% in patients without LV dysfunction, P = 0.044) and an increased incidence of serious cardiac events (81.6 vs. 28.6%, P < 0.001). CONCLUSIONS: This study provides the first evidence that, besides advanced age and prolonged myocardial ischemic time, LV diastolic dysfunction characterized by Vp <or= 40 cm/sec identifies patients who will require cardiovascular support following valve replacement for aortic stenosis.
35
James Brown, Sean M. O’Brien, Changfu Wu et al. · Journal of Thoracic and Cardiovascular Surgery · 2009 · 937 citations · Full text
Medicine, Cardiology, Surgery +14
Todd Dewey, David L. Brown, William H. Ryan et al. · Journal of Thoracic and Cardiovascular Surgery · 2007 · 409 citations · Full text
Predictors of low cardiac output syndrome after coronary artery bypass
Vivek Rao, Joan Ivanov, Richard D. Weisel et al. · Journal of Thoracic and Cardiovascular Surgery · 1996 · 288 citations · Full text
Medicine, Cardiology, Surgery +14
Daniel Wendt, Brigitte Osswald, Katrin Kayser et al. · The Annals of Thoracic Surgery · 2009 · 227 citations