Journal of Magnetic Resonance Imaging · 2010 · 314 citations · 18 references
MedicineNeuroscienceRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyBrain ImagingCerebrovascular ImagingMagnetic Resonance Image ReconstructionMagnetic Resonance ImagingMedical ImagingVascular ImagingCerebral Vascular ImagingK-spaceMagnetic Susceptibility MappingOxygen SaturationOxygen Saturation MeasurementSusceptibility-weighted ImagingVascular VisualizationVenous Mapping
PURPOSE: To create an orientation-independent, 3D reconstruction of the veins in the brain using susceptibility mapping. MATERIALS AND METHODS: High-resolution, high-pass filtered phase images usually used for susceptibility weighted imaging (SWI) were used as a source for local magnetic field behavior. These images were subsequently postprocessed using an inverse procedure to generate susceptibility maps of the veins. Regularization and interpolation of the data in k-space of the phase images were used to reduce reconstruction artifacts. To understand the effects of artifacts, and to fine-tune the methodology, simulations of blood vessels were performed with and without noise. RESULTS: With sufficient resolution, major veins in the brain could be visualized with this approach. The usual geometry-dependent phase dipole effects are removed by this processing, leaving basically images of the veins. Different sized vessels show a different level of contrast depending on their partial volume effects. Vessels that are 8 mm or 16 mm in size show quantitative values expected for normal oxygen saturation levels. Smaller vessels show smaller values due to errors in the methodology and due to partial volume effects. Larger vessels show a bias toward a reduced susceptibility approaching 90% of the expected value. Limitations of the method and artifacts related to different sources of errors are demonstrated. CONCLUSION: Susceptibility maps can successfully create venograms of the brain with varying levels of contrast-to-noise depending on the size of the vessel. Partial volume effects render this approach more useful as an imaging tool or a visualization tool, although certain larger vessels have measured susceptibilities close to expected values associated with normal blood oxygen saturation levels.
18
Susceptibility weighted imaging (SWI)
E. Mark Haacke, Yingbiao Xu, Yu‐Chung N. Cheng et al. · Magnetic Resonance in Medicine · 2004 · 1.6K citations
Tian Liu, Pascal Spincemaille, Ludovic de Rochefort et al. · Magnetic Resonance in Medicine · 2008 · 468 citations · Full text
Natural Sciences, Physics, Radiology +17