Neurorehabilitation and neural repair · 2007 · 46 citations · 34 references
Life SciencesNeurologyNeuroscienceClinical NeuroscienceMotor NeuroscienceStroke RehabilitationMotor Cortex StimulationMotor RecoveryStrokeAdult Intelligence AssessmentDepressant ActionLow-frequency StimulationPost-stroke RehabilitationTranscranial Magnetic StimulationTreatment Adverse EffectsVerbal Learning TestsWechsler Intelligence Scales
BACKGROUND: Suppression of activity in the contralesional motor cortex may promote recovery of function after stroke. Furthermore, the known depressant effects of low-frequency repetitive transcranial magnetic stimulation (rTMS) can be increased and prolonged by preceding it with 6-Hz priming stimulation. OBJECTIVE: The authors explored the safety of 6-Hz primed low-frequency rTMS in 10 patients with ischemic stroke. METHODS: Priming consisted of 10 minutes of 6-Hz rTMS applied to the contralesional hemisphere at 90% of resting motor threshold delivered in 2 trains/min with 5 s/train and 25-second intervals between trains. Low-frequency rTMS consisted of an additional 10 minutes of 1-Hz rTMS at 90% of resting motor threshold without interruption. Possible adverse effects were assessed with the National Institutes of Health Stroke Scale (NIHSS), the Wechsler Adult Intelligence Scale-Third Edition (WAIS-III), the Hopkins Verbal Learning Test-Revised (HVLT-R), the Beck Depression Inventory-Second Edition (BDI-II), a finger movement tracking test, and individual self-assessments. Pretest, treatment, and posttest occurred on the first day with follow-up tests on the next 5 weekdays. RESULTS: There were no seizures and no impairment of NIHSS, WAIS-III, or BDI-II scores. Transient impairment occurred on the HVLT-R. Transient tiredness was common. Occasional reports of headache, neck pain, increased sleep, reduced sleep, nausea, and anxiety occurred. CONCLUSION: Because there were no major adverse effects, the authors concluded that the treatment was safe for the individuals in this study and that further investigation is now warranted to examine efficacy and safety of serial treatments of 6-Hz primed low-frequency rTMS.
34
Marshal F. Folstein, Susan E. Folstein, Paul R. McHugh · Journal of Psychiatric Research · 1975 · 86.9K citations
An Inventory for Measuring Depression
Aaron T. Beck · Archives of General Psychiatry · 1961 · 38.2K citations
The assessment and analysis of handedness: The Edinburgh inventory
R. C. Oldfield · Neuropsychologia · 1971 · 36.7K citations
Eric M. Wassermann · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · 1998 · 2.3K citations