IEEE Transactions on Medical Imaging · 2003 · 39 citations · 34 references
Natural SciencesBiomedical EngineeringBiophysicsBiomedical OpticsBiophotonicsDiagnostic ImagingCellular ImagingFluorescence ImagingFluorescence MicroscopyImage QuantificationOptical TomographyTissue Optical PropertiesAdjoint FormulationData InversionFluorescence Image ReconstructionFluorescence TomographyInverse Problems In Optical TomographyJacobian Matrix ApproximationNonlinear Least SquaresSensitivity
Many approaches to fluorescence tomography utilize some form of regularized nonlinear least-squares algorithm for data inversion, thus requiring repeated computation of the Jacobian sensitivity matrix relating changes in observable quantities, such as emission fluence, to changes in underlying optical parameters, such as fluorescence absorption. An exact adjoint formulation of these sensitivities comprises three terms, reflecting the individual contributions of 1) sensitivities of diffusion and decay coefficients at the emission wavelength, 2) sensitivities of diffusion and decay coefficients at the excitation wavelength, and 3) sensitivity of the emission source term. Simplifying linearity assumptions are computationally attractive in that they cause the first and second terms to drop out of the formulation. The relative importance of the three terms is thus explored in order to determine the extent to which these approximations introduce error. Computational experiments show that, while the third term of the sensitivity matrix has the largest magnitude, the second term becomes increasingly significant as target fluorophore concentration or volume increases. Image reconstructions from experimental data confirm that neglecting the second term results in overestimation of sensitivities and consequently overestimation of the value and volume of the fluorescent target, whereas contributions of the first term are so low that they are probably not worth the additional computational costs.
34
Optical tomography in medical imaging
Simon Arridge · Inverse Problems · 1999 · 2.5K citations
Receptor-targeted optical imaging of tumors with near-infrared fluorescent ligands
Andreas Becker, Carsten Hessenius, Kai Licha et al. · Nature Biotechnology · 2001 · 520 citations
Fluorescence lifetime imaging in turbid media
M. A. O’Leary, David A. Boas, X. D. Li et al. · Optics Letters · 1996 · 290 citations
Bruce J. Tromberg, Olivier Coquoz, Joshua B. Fishkin et al. · Philosophical Transactions of the Royal Society B Biological Sciences · 1997 · 266 citations · Full text