Retained ophthalmic viscosurgical device material in the capsular bag 6 months after phacoemulsification

Galina Sholohov, Shmuel Levartovsky

Journal of Cataract & Refractive Surgery · 2005 · 10 citations · 5 references

Concepts

Abstract

We present a 63-year-old man who developed low-grade endophthalmitis 6 months after phacoemulsification and implantation of a foldable posterior chamber intraocular lens (IOL). The capsular bag was distended, but shallowing of the anterior chamber was not observed. Chemical analysis of the clear fluid aspirated from the capsular bag behind the IOL revealed the presence of an ophthalmic viscosurgical device.

References

5