An adaptive linear combiner for on-line tracking of power system harmonics

P.K. Dash, D.P. Swain, A.C. Liew, Saifur Rahman

IEEE Transactions on Power Systems · 1996 · 212 citations · 10 references

Concepts

TL;DR

The paper proposes a linear adaptive neuron (Adaline) to estimate harmonic components in power systems. The method adapts the Adaline’s learning parameters to enforce a stable error equation and is validated through numerical tests on noisy, DC‑decaying power‑system signals. The estimator accurately tracks Fourier coefficients of noisy, DC‑decaying signals, demonstrating that harmonic components can be tracked easily with this algorithm.

Abstract

The paper presents a new approach for the estimation of harmonic components of a power system using a linear adaptive neuron called Adaline. The learning parameters in the proposed neural estimation algorithm are adjusted to force the error between the actual and desired outputs to satisfy a stable difference error equation. The estimator tracks the Fourier coefficients of the signal data corrupted with noise and decaying DC components very accurately. Adaptive tracking of harmonic components of a power system can easily be done using this algorithm. Several numerical tests have been conducted for the adaptive estimation of harmonic components of power system signals mixed with noise and decaying DC components.

References

10