2002 · 55 citations · 11 references
EngineeringElectrical EngineeringWater Resources ManagementEnergy SystemsPower ElectronicsRenewable Energy SystemsPhotovoltaic DevicesRenewable Energy Power ConversionSolar Energy SystemsSolar IrradianceSolar Photovoltaic SystemsWater Power SystemsIrradianceLoad MatchingPhotovoltaic System OptimizationPower Conversion EfficiencyPower OutputReconfiguration Controller DesignSolar Photovoltaic Power SystemsSolar Powered Water Pumping
The authors present a technique for finding the irradiance levels for optimum switching of photovoltaic (PV) powered water pumping systems operating with a multistage electrical array reconfiguration controller (EARC). Depending on the starting current requirements and the irradiance levels, the EARC reconfigures a PV array to be in parallel connection at a low irradiance level and in series connection at a high irradiance level. In this way, the quality of load matching in a PV power system will be improved because at low irradiance levels the power available to the motor in parallel connection is greater than the power available in a series connection and vice versa at higher irradiance levels. Optimum switching occurs when the power output of a parallel-connected array equals the power output of a series-connected array for a given irradiance level.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
11