IEEE Transactions on Industry Applications · 2002 · 89 citations · 9 references
EngineeringElectrical EngineeringMining EngineeringCondition AssessmentElectric MachinesMaintenance EngineeringCondition MonitoringCondition-based MaintenanceElectric MotorsFault DetectionInduction MachinesMachine WindingsCurrent UnbalanceInduction MotorsMachine Condition MonitoringMotor Condition MonitoringMotor Fault DiagnosisMotor WindingsOnline MonitoringVoltage Unbalance
Condition monitoring of induction motors enables early detection of winding deterioration, allowing scheduled maintenance in mining and other industrial settings without production loss. The study presents a theoretical and experimental analysis of a voltage mismatch technique for monitoring induction motor winding health. The method demonstrates robustness under power supply unbalance, construction imperfections, and unpredictable loads, and includes a suggested industrial application procedure.
Condition monitoring of induction motors is a process that may be used to great advantage in mining and other industrial applications. The early detection of motor winding deterioration prior to a complete failure provides an opportunity for maintenance to be performed on a scheduled routine without the loss of production time. Presented in this paper is a theoretical and experimental analysis of a voltage mismatch technique that may be used in operating situations to monitor the health of induction motor windings. It extends previous work in this area by demonstrating the robust nature of the monitoring process not only under conditions of power supply unbalance but also in situations where motor construction imperfections exist and mechanical loads are unpredictable. A suggested procedure for application of this condition monitoring process in industrial situations is also included.
9
Inter-turn stator winding fault diagnosis in three-phase induction motors, by Park's vector approach
António J. Marques Cardoso, Sérgio M. A. Cruz, D. S. B. Fonseca · IEEE Transactions on Energy Conversion · 1999 · 307 citations · Full text
Engineering, Electrical Engineering, Automotive Diagnostics +16
A new approach to on-line turn fault detection in AC motors
G.B. Kliman, William Premerlani, R.A. Koegl et al. · 2002 · 300 citations