Clinical Oral Implants Research · 2011 · 120 citations · 26 references
DentistryImplant DentistryPeriodonticsImplant SurgeryPeri-implant DiseasesPeriodontal MedicineImplant SurvivalPeri-implant Bone Level AssessmentPeri-implant Tissue HealthPeriodontal Status EvaluationClinical Survival RatesImplant Survival AnalysisImplant Survival RatesLong-term Implant SurvivalMarginal Bone Level ChangesMarginal Bone Level MeasurementMarginal Bone Loss AnalysisPlaque Indices
OBJECTIVES: Retrospectively evaluate the survival, radiographic and peri-implant outcome of single turned Brånemark™ implants after at least 16 years. MATERIALS AND METHODS: From 134 patients (C-group), 101 could be contacted concerning implant survival and 50 (59 remaining implants) were clinically examined (I-group). Marginal bone level was radiographically measured from the implant-abutment junction at baseline (=within 6 months after abutment connection) and 1-4, 5-8 and 16-22 years post-operatively. Probing depth, gingival and plaque index were measured. Marginal bone-level changes were analyzed using Friedman's and Wilcoxon's signed ranks tests. Spearman's correlations between radiographic and clinical parameters were calculated. RESULTS: In the C-group, 13 out of 166 implants in 11 out of 134 patients failed (CSR=91.5%). In the I-group (28 males-22 females; mean age 23.9 years at baseline; range 14-57), the mean follow-up was 18.4 years (range 16-22). The mean bone level was 1.7±0.88 mm (range -0.8 to 5) after 16-22 years. Changes in the mean marginal bone level were statistically significant between baseline and the second measuring interval (1-4 years). Thereafter, no significant differences could be demonstrated. The mean interproximal probing depth, gingival and plaque indices were 3.9±1.27 mm, 1.2±0.81 and 0.2±0.48, respectively. Probing depth was moderately correlated with gingival inflammation (r=0.6; P<0.001) but not with bone level (P>0.05). 81.4% of the implants had a bone level ≤2nd thread and 91.5% had a probing depth ≤5 mm. 76.3% had both bone level ≤2nd thread and probing depth ≤5 mm. CONCLUSIONS AND CLINICAL IMPLICATIONS: The single turned Brånemark™ implant is a predictable solution with high clinical survival and success rates. In general, a steady-state bone level can be expected over decades, with minimal signs of peri-implant disease. A minority (5%), however, presents with progressive bone loss.
26
Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period.
R Adell, U. Breine, Johan Lindström et al. · PubMed · 1977 · 2.4K citations