Radiology · 2006 · 72 citations · 25 references
MedicineObstetricsRadiologyDiagnostic ImagingDiagnostic RadiologyMaternal-fetal MedicineFetal Anatomy AssessmentFetal ImagingMagnetic Resonance ImagingPrenatal ImagingFast Spin EchoFetal Magnetic Resonance ImagingFetal MriGestational Age MeasurementInstitutional Review Board ApprovalLung Volume AssessmentLung Volume EstimationMagnetic Resonance
PURPOSE: To retrospectively determine the effect of gestational age (GA), imaging plane, section thickness, and inter- and intraobserver variability on fetal lung volume (FLV) measurements obtained with magnetic resonance (MR) imaging in a cohort of fetuses without thoracic abnormalities. MATERIALS AND METHODS: Institutional review board approval was obtained. Informed consent for this retrospective cohort study was waived, and the conduct of this study was HIPAA compliant. FLV was measured in 30 fetuses (GA, 17-36 weeks) referred for MR imaging for indications other than pulmonary abnormalities. Measurements were made on single-shot fast spin-echo images by tracing free-form regions of interest on individual consecutive sections in the transverse, sagittal, and coronal planes. Measurements were performed twice by two observers independently. Correlations between FLV and GA, imaging plane, and section thickness were assessed, as were intra- and interobserver variability. Time to perform FLV was assessed in a subset of fetuses. RESULTS: Total FLV ranged from 2 to 110 mL. Mixed-effects regression model showed significant quadratic trend in FLV with increasing GA, with comparable strength of correlation (r = 0.89-0.91) in the three imaging planes of measurement. Intraobserver agreement was good in all three planes (r = 0.65-0.83) and was highest in the transverse plane. Interobserver agreement was good in all three planes (r = 0.68-0.76). FLV showed no significant dependence on section thickness (P = .23) or imaging plane (P = .82). Mean time to obtain FLV measurements ranged from 48 seconds at GA of 21 weeks to 77 seconds at GA of 29-30 weeks. CONCLUSION: GA-based FLV measurements obtained with MR images are independent of section thickness and imaging plane and can be performed with good inter- and intraobserver agreement in less than 2 minutes.
25
Sonographic predictors of survival in fetal diaphragmatic hernia
Andrea P Metkus, Roy A. Filly, Mark D. Stringer et al. · Journal of Pediatric Surgery · 1996 · 661 citations
Fetal Lung Volume: Estimation at MR Imaging—Initial Results
Françoise Rypens, Thierry Metens, N. Rocourt et al. · Radiology · 2001 · 335 citations
Medicine, Obstetrics, Radiology +17
Congenital Chest Lesions: Diagnosis and Characterization with Prenatal MR Imaging
Anne M. Hubbard, N. Scott Adzick, Timothy M. Crombleholme et al. · Radiology · 1999 · 224 citations
Medicine, Obstetrics, Radiology +17
MR imaging of the fetus by a HASTE sequence.
Yo‐ichi Yamashita, Tomohiro Namimoto, Yasuko Abe et al. · American Journal of Roentgenology · 1997 · 213 citations
Medicine, Obstetrics, Radiology +17