Charge Partitioning at Gas−Solid Interfaces: Humidity Causes Electricity Buildup on Metals

Telma R. D. Ducati, Luís H. Simões, Fernando Galembeck

Langmuir · 2010 · 123 citations · 24 references

DOIFull text

Open access

Concepts

Abstract

Isolated metals within Faraday cages spontaneously acquire charge at relative humidity above 50%: aluminum and chrome-plated brass become negative, stainless steel is rendered positive, and copper remains almost neutral. Isolated metal charging within shielded and grounded containers confirms that the atmosphere is an electric charge reservoir where OH(-) and H(+) ions transfer to gas-solid interfaces, producing net current. The electricity buildup dependence on humidity, or hygroelectricity, acts simultaneously but in opposition to the well-known charge dissipation due to the increase in surface conductance of solids under high humidity. Acknowledging this dual role of humidity improves the reproducibility of electrostatic experiments.

References

24