Pediatric Anesthesia · 2009 · 18 citations · 34 references
MedicineAnesthesiologyAnesthesiaPediatric AnesthesiologyRegional AnesthesiaElectroencephalographyInfant AnesthesiaPediatric AnesthesiaAnesthesia MonitoringAnesthetic Effects On Neurophysiological SignalsAnesthetic PremedicationInstitutional Review Board AdministrationInstitutional Review Board ApprovalMixed Model MethodologySevoflurane AnesthesiaStatistical Significance Testing
BACKGROUND: Devices that monitor the depth of anesthesia are increasingly used to titrate sedation and avoid awareness during anesthesia. Many of these monitors are based upon electroencephalography (EEG) collected from large adult reference populations and not pediatric populations (Anesthesiology, 86, 1997, 836; Journal of Anaesthesia, 92, 2004, 393; Anesthesiology, 99, 2003, 34). We hypothesized that EEG patterns in children would be different from those previously reported in adults and that they would show anesthetic-specific characteristics. METHODS: This prospective observational study was approved by the Institutional Review Board, and informed written consent was obtained. Patients were randomized to receive maintenance anesthesia with isoflurane or sevoflurane. EEG data collection included at least 10 min at steady-state maintenance anesthesia. The EEG was recorded continuously through emergence until after extubation. A mixed model procedure was performed on global and regional power by pooled data analysis and by analyzing each anesthetic group separately. Statistical significance was defined as P < 0.05. RESULTS: Thirty-seven children completed the study (ages 22 days-3.6 years). Isoflurane and sevoflurane had different effects on global and regional EEG power during emergence from anesthesia, and frontal predominance patterns were significantly different between these two anesthetic agents. CONCLUSIONS: The principal finding of the present study was that there are anesthetic-specific and concentration-dependent EEG effects in children. Depth-of-anesthesia monitors that utilize algorithms based on the EEGs of adult reference populations therefore may not be appropriate for use in children.
34
Scalp electrode impedance, infection risk, and EEG data quality
Thomas C. Ferrée, Phan Luu, Gerald S. Russell et al. · Clinical Neurophysiology · 2001 · 1K citations
The Pharmacology of Sevoflurane in Infants and Children
Jerrold Lerman, Nancy Sikich, Sam Kleinman et al. · Anesthesiology · 1994 · 524 citations
Invariant Reversible QEEG Effects of Anesthetics
E. Roy John, Leslie S. Prichep, W. J. Kox et al. · Consciousness and Cognition · 2001 · 279 citations