Infrared Screening of Residential Buildings for Energy Audit Purposes: Results of a Field Test

Giuliano Dall’O’, Luca Sarto, Angela Panza

Energies · 2013 · 130 citations · 11 references

DOIFull text

Open access

Concepts

TL;DR

The EU building sector accounts for about 40 % of energy consumption, yet the existing stock is inefficient and requires retrofitting, and thermography is widely used to non‑invasively identify such inefficiencies. The study aims to supply energy‑performance data through infrared audits of 14 Milan Province buildings spanning different construction periods. Infrared thermography was employed to estimate wall U‑values, which were then compared to known values to evaluate the method’s reliability and error margin. The method proved sufficiently reliable for solid‑mass structure buildings, but exhibited high deviation for buildings with insulated external walls.

Abstract

In the European Union (EU), the building sector is responsible for approximately 40% of total energy consumption. The existing building stock is inefficient and can, and indeed must be retrofitted to address this issue. The practical implementation of the European strategies requires knowledge of the energy performance of existing buildings through energy audit techniques. Application of thermography in the fields of energy are very widespread, since, through such a non-invasive investigation, and through correct interpretation of infrared images, it is possible to highlight inefficiencies in buildings and related facilities. The paper shows and discusses the results of an infrared audit campaign on 14 existing buildings located in Milan Province (Italy) made in different construction periods and characterised, therefore, by different building technologies. The U-values obtained in an indirect way through the thermography of the opaque walls of the buildings investigated, were compared with the actual known values in order to verify the reliability of the method and the possible margin of error. The study indicated that the category of buildings in which the application of this method is sufficiently reliable is that of solid-mass structure buildings, the most widespread in Italy, whereas in the case of buildings whose external walls are insulated, the percentage of deviation is very high.

References

11