EngineeringPositron Annihilation SpectroscopyMicroscopyAnalytical MicrosystemsElectron MicroscopyInstrumentationMicrofluidicsMicrochannel PlateBiophysicsPhysicsScreen AssemblyMicroanalysisMicrochannel Plate/phosphor DetectorMicrofabricationConfined AntiprotonsApplied PhysicsElectron MicroscopeDetector PhysicMedicine
A microchannel plate (MCP)/phosphor screen assembly has been used to destructively measure the radial profile of cold, confined antiprotons, electrons, and positrons in the ALPHA experiment, with the goal of using these trapped particles for antihydrogen creation and confinement. The response of the MCP to low energy (10-200 eV, <1 eV spread) antiproton extractions is compared to that of electrons and positrons.