Blood Pressure Changes During Retrograde Brachial Angiography

Joseph P. Lin, Irvin I. Kricheff, Norman E. Chase

Radiology · 1964 · 48 citations · 0 references

Concepts

Abstract

Investigation of the vascular system by angiographic technics requires the rapid injection of varying amounts of foreign material. This produces numerous chemical and physiological changes in the patient (3, 6, 7, 11, 14). Many of these parameters have been studied previously; however, we have been unable to find any serious investigation of intra-arterial pressure changes during the actual performance of angiography in man. The purpose of this study was to investigate the pressure changes that might occur during and shortly after retrograde brachial angiography, as measured in the brachial artery proximal to the injection site, the carotid arteries, and the systemic circulation as represented by the femoral artery. Material and Methods Our technic of retrograde brachial angiography consists of percutaneous puncture of the brachial artery in the mid-forearm with a 15- or 16-gauge Cournand needle and the injection of 30 c.c. of 50 per cent sodium diatrizoate (50 per cent Hypaque, Squibb) with 15 c.c. of saline floating above the contrast material. The injection is made with an automatic injector (Taveras, Picker) set at a pressure of 625 lb. per square inch. Injection time is between one-half and one second. This technic has previously been described in detail (4). For the purposes of this investigation, an additional 16-gauge Cournand needle was inserted into the brachial artery from 5 to 12 cm. above the initial puncture site for brachial recordings. Sixteen-gauge Cournand needles were employed for femoral artery recordings and 18-gauge needles for carotid artery measurements. Pressures were measured by a pressure transducer (Statham P 23AC) and recorded on a Grass Model 5 polygraph. The entire system was calibrated against a mercury manometer. Pressure recordings were made before, during, and after injections of contrast material, contrast material and saline, and saline alone, in volumes of 5 to 60 c.c. Injection pressures ranged from 125 to 625 lb. per square inch. A total of 81 measurements were made in 25 adults, most of whom were being studied for cerebrovascular disease. Results Sixty brachial recordings were obtained in 17 patients, including 2 subjected to simultaneous brachial and femoral recordings. Sixteen measurements were made during the actual angiographic procedure under the conditions previously described. The pattern of pressure response was similar in 14 cases. Simultaneous with the injection, there was elevation of brachial systolic blood pressure from 15 to 100 mm. Hg lasting for an average of one and three-tenths seconds with a range of two-tenths to three seconds. The pressure then returned to preinjection levels for one to five seconds, followed by a depression of systolic blood pressure from 15 to 40 mm. Hg for five to twenty-four seconds, after which it reverted to pre-injection levels (Fig. 1).