Tonometric Measurement of Dental Pulpal and Mandibular Marrow Blood Pressures

Richard L. Christiansen, Maurice W. Meyer, Maurice B. Visscher

Journal of Dental Research · 1977 · 18 citations · 16 references

Concepts

Abstract

Dental pulpal and mandibular marrow vascular pressures were studied with a tonometric method under conditions of autoperfusion and step flow controlled perfusion. The tonometric pulpal and marrow pressures averaged 17 +/- 5 mm Hg and 20 +/- 6 mm Hg, respectively. The venous end pressure was 16 +/- 8 mm Hg at a perfusion pressure of 156 +/- 28 mm Hg. The tonometric pulpal pressures were lower and were less variable than the comparable canulation pulpal pressures.

References

16