Radiation Protection Dosimetry · 2010 · 22 citations · 12 references
EngineeringBuilding ScienceNuclear EngineeringRadiation DetectionRadiation DosimetryRadiation MeasurementBackground Radiation MeasurementNuclear DecayRadiation HealthRadiation Risk AssessmentRadioactive DecayRadioactive PollutionRadonRadon Background MeasurementRadon MeasurementRadon MonitoringSolid State Nuclear Track DetectionSolid-state DetectorsSolid-state Track DetectorsTrack Detectors
Using the Raduet discriminative radon-thoron solid-state nuclear track detectors, a limited number of measurements were recently carried out about 1 m away from any wall and 1.5 m above the floor in different environments in Slovenia. The following thoron and radon ranges were obtained, respectively (Bq m(-3)): 33-700 and 25-4900 in 2 dwellings, 11-215 and 22-422 in 5 kindergartens, 21-368 and 40-4609 in 35 elementary schools, 47-1361 and 92-3280 in 4 hospitals, 4-37 and 10-153 in 9 spas and 800-880 and 4060-6870 in 1 karst cave (2 places). In case of thoron and radon concentrations lognormal distribution was confirmed, while the statistical relationship between them was weak.
12
Radon and Thoron Exposures for Cave Residents in Shanxi and Shaanxi Provinces
Shinji Tokonami, Quanfu Sun, Suminori Akiba et al. · Radiation Research · 2004 · 100 citations · Full text
Preliminary results of simultaneous radon and thoron tests in Ottawa
J. Chen, Shinji Tokonami, Atsuyuki Sorimachi et al. · Radiation Protection Dosimetry · 2007 · 62 citations · Full text