British Journal of Radiology · 1965 · 28 citations · 9 references
MedicineRadiologyRadiation DosimetryRadiation PhysicsTreatment PlanningAbsorbed DoseElectron DosimetryExternal Beam DosimetryRadiation Dose MeasurementRadiation TherapyTreatment Planning Dose CalculationDensityDepth Dose DistributionElectron Dose DistributionHigh-energy Particle RadiationIsodose DistributionRadiation Dose AssessmentRadiation Dose EstimationTissue Inhomogeneity Correction
In common with other radiations the actual distribution of dose produced in a patient by high energy electron irradiation is strongly dependent on the composition of the body in the path of the beam. A system in use for the modification of unit density isodose distributions is briefly described. Since the absorption of electrons is determined by quite different processes from those applicable to X rays this system was based on the specific characteristics of electron absorption. Correction in this system starts with the representation of an isodose distribution by several depth dose distributions along axes emanating from a virtual source. Segments of these unit density depth dose distributions are translated sequentially by amounts dependent on the location, extent, and electron density of the inhomogeneous region. The various steps in this system have been briefly presented and lead to the corrected dose in and beyond a region of lower density, such as lung, and correct for the effects of both attenuation and scatter. In the case of limited regions of higher density and higher atomic number, such as bone, this method provides for the systematic correction of the dose beyond the inhomogeneity. The enhancement of dose in bone with electrons is rarely large enough to be clinically significant and is separately computed on the basis of experimental measurements made with different amounts of bone equivalent material. The differences between the corrected actual distribution of dose in the patient and that indicated by uncorrected unit density distributions are so significant that such corrections would appear to be essential if the physical advantages of high energy radiation therapy are to be realised in practice.
9
Some Physical Aspects of Electron Beam Therapy
J. S. Laughlin, J. Ovadia, John W. Beattie et al. · Radiology · 1953 · 55 citations
Medicine, Radiology, Nuclear Physics +13
A. Batchelor, D. K. Bewley, R. J. Morrison et al. · British Journal of Radiology · 1959 · 34 citations
RADIATION THERAPY WITH HIGH-ENERGY ELECTRONS USING PENCIL BEAM SCANNING.
J. W. J. Carpender, L S SKAGGS, L. H. Lanzl et al. · PubMed · 1963 · 20 citations
Radiation Therapy with High-Energy Electrons
L. M. Zatz, Carl F. von Essen, Hillard Kaplan · Radiology · 1961 · 16 citations