Increased Ventricular Fibrillation during Coronary Arteriography with a New Contrast Medium Preparation

Sven Paulin, Douglass F. Adams

Radiology · 1971 · 49 citations · 12 references

Concepts

Abstract

A canine model was used to investigate the recent increased incidence of ventricular fibrillation associated with the use of a new low-sodium preparation Renografin 76% during selective coronary arteriography. A marked increase of ventricular fibrillation was noted from two different contrast agents when total sodium content was significantly below normal serum levels. Ventricular fibrillation was not preceded by alterations in normal sinus activity, and it was not related to other parameter changes of contrast toxicity (EKG deflections, atrial or aortic pressure change). Rather than below, an optimum sodium level appears to be near normal serum levels.

References

12