MedicineOrthopaedic SurgeryOrthopedic SurgeryBone ScintigraphyJoint Replacement SurgeryOrthopedicsHip ArthroplastyThree-phase Bone ScintigraphyCemented Revision ArthroplastyIndium-111 Labeled Leukocyte ImagingPostoperative Bone ScintigraphyPostoperative Hip ImagingRadiolabeled White Blood Cell ScintigraphyRadionuclide Bone ScintigraphyScintigraphic Uptake InterpretationWhite Blood Cell Imaging
Although few studies address the use of three-phase bone scanning (TPBS) and indium-111-labeled white blood cell scintigraphy (111In-WBC) in hip arthroplasty utilizing a porous-coated prosthesis, the literature suggests that scintigraphic patterns in the uncomplicated patient may differ form that seen with the cemented prosthesis. In an attempt to determine the scintigraphic natural history, 25 uncomplicated porous-coated hip arthroplasties in 21 patients were prospectively studied with serial TPBS and 111In-WBC at approximately 7 days, and 3, 6, 12, 18, and 24 mo postoperatively. This report deals with findings related to the acetabulum. All 25 prostheses (144 of 144 scans) demonstrated increased uptake on the bone-phase images. Although this activity decreased with time, 76% had persistent uptake at 24 mo. Twenty-three of 25 prostheses (126 of 140 scans) showed increased uptake on 111In-WBC scintigraphy, invariably decreasing with time, but with 37% having significant uptake at 24 mo. Scintigraphic patterns in the uncomplicated porous-coated hip arthroplasty patient appear to differ from patterns described in cemented prostheses.
3
Biological fixation of porous-coated implants
Ralph Haddad, S. D. Cook, Kevin A. Thomas · Journal of Bone and Joint Surgery · 1987 · 142 citations