Journal of Bone and Joint Surgery - British Volume · 2000 · 91 citations · 27 references
MedicineOrthopedic SurgerySurgeryBone GraftingOrthopaedic BiomaterialsOrthopedicsAutogenous Bone GraftsBone Defect ReconstructionBone ReconstructionCancellous Bone GraftingDistal Humerus Fracture SurgeryProximal Humerus FracturesAutogenous GraftingBone Defect BridgingCancellous Bone GraftsDistal Humerus Fracture ReconstructionFracturesHumeral Head DefectsHumeral ReconstructionOrthopaedic Bone Repair
We treated 15 patients with atrophic nonunion of a diaphyseal fracture of the humerus with an associated bony defect using an autogenous cancellous bone graft and a plate to bridge the defect. There were nine men and six women with a mean age of 48 years. The mean length of the bony defect was 3 cm. At a mean follow-up of 30 months only one fracture failed to unite. This suggests that, in the presence of a well-vascularised envelope of muscle, the application of an autogenous cancellous bone graft in conjunction with a bridging plate represents a good alternative to more demanding surgical techniques.
27