EngineeringCivil EngineeringEarthquake EngineeringSeismic DesignStructural EngineeringFiber-reinforced CompositesReinforced Concrete StructuresSeismic Retrofit Of StructuresStructural DesignStructural ReinforcementStructural RetrofittingAxial Load ResponseColumn StrengtheningColumnsExperimental Study DesignReinforced ConcreteReinforced Concrete RetrofitReinforced Concrete Seismic ResponseSeismic Retrofit
This paper presents the results of an experimental study on the application of pre-stressed high strength metal strips in retrofit of RC columns. Six 2/3 scale were deliberately designated with insufficient transverse reinforcement details and tested under constant axial and cyclic lateral load reversals. The level of axial load and the pattern of strengthening were parameters of this study. It was observed that the technique has been capable to enhance the lateral behavior of columns significantly, in terms of ductility. Very ductile behavior was obtained. The height-wise variations of lateral strain on confining strips are studied. The analysis of the fiber-based model of tested columns showed good agreement with experiments.