A quantitative antiglobulin test for IgG for use in blood transfusion serology

Anthony H. Merry, Eileen E. Thomson, Violet I. Rawlinson, F. Stratton

Clinical & Laboratory Haematology · 2008 · 60 citations · 23 references

Abstract

A sensitive method has been developed using 125I-labelled anti-IgG which allows detection of IgG present on the red cell surface. By suitable absorption and correction for non-specific binding to trypsinized red cells, a reproducible, accurate method of quantitating IgG absorbed onto red cells is obtained. The number of IgG molecules present on normal cells was found to range from 5 to 90 with an average of 39. Studies of correlation of agglutination in the antiglobulin test with numbers of IgG molecules on the cell were also undertaken.

References

23