Radiology · 1992 · 30 citations · 0 references
DentistryMaxillofacial RadiologyOral RadiologyDiagnostic ImagingImage InterpretationRadiographic AnatomyImaging AssessmentMagnetic Resonance ImagingTemporomandibular Joint AnatomyTemporomandibular Joint ImagingTemporomandibular Joint InterpretationTemporomandibular Joint RadiographyDiagnostic Accuracy StudiesImage Quality MetricsSection Thickness OptimizationSpin ResonanceTemporomandibular Joint Imaging InterpretationTemporomandibular Joint MorphologyTrabecular ArchitectureTrabecular Bone Pattern Assessment
To determine if the quality of spin-echo magnetic resonance (MR) images of the temporomandibular joint (TMJ) could be improved by reducing section thickness, coronal and sagittal 3.0- and 1.5-mm MR images of the same joints were evaluated. Depiction of the disk, trabecular pattern, and cortex of the condyle was better on coronal 1.5-mm images than on 3.0-mm images (P less than .01), and 1.5-mm sagittal images were better for depiction of the trabecular pattern of the condyle than were 3.0-mm images (P less than .05). The ability of MR imaging with thinner sections to reveal more anatomic details should result in improved diagnostic accuracy.