Computer Methods in Biomechanics & Biomedical Engineering · 2013 · 105 citations · 42 references
MedicineBiomedical EngineeringComputational EngineeringCardiothoracic SurgeryFinite Element AnalysisInterventional CardiologyCardiac Valve SurgerySurgical Valve ReplacementTranscatheter Aortic Valve ReplacementTranscatheter Valve TherapyBalloon Inflation PressureHeart Valve ModelingProsthetic Device EvaluationTranscatheter Valve CoaptationValve Deployment Technique
Until recently, heart valve failure has been treated adopting open-heart surgical techniques and cardiopulmonary bypass. However, over the last decade, minimally invasive procedures have been developed to avoid high risks associated with conventional open-chest valve replacement techniques. Such a recent and innovative procedure represents an optimal field for conducting investigations through virtual computer-based simulations: in fact, nowadays, computational engineering is widely used to unravel many problems in the biomedical field of cardiovascular mechanics and specifically, minimally invasive procedures. In this study, we investigate a balloon-expandable valve and we propose a novel simulation strategy to reproduce its implantation using computational tools. Focusing on the Edwards SAPIEN valve in particular, we simulate both stent crimping and deployment through balloon inflation. The developed procedure enabled us to obtain the entire prosthetic device virtually implanted in a patient-specific aortic root created by processing medical images; hence, it allows evaluation of postoperative prosthesis performance depending on different factors (e.g. device size and prosthesis placement site). Notably, prosthesis positioning in two different cases (distal and proximal) has been examined in terms of coaptation area, average stress on valve leaflets as well as impact on the aortic root wall. The coaptation area is significantly affected by the positioning strategy (- 24%, moving from the proximal to distal) as well as the stress distribution on both the leaflets (+13.5%, from proximal to distal) and the aortic wall (- 22%, from proximal to distal). No remarkable variations of the stress state on the stent struts have been obtained in the two investigated cases.
42
Heart Disease and Stroke Statistics—2010 Update
Donald M. Lloyd‐Jones, Robert J. Adams, Todd M. Brown et al. · Circulation · 2009 · 5.6K citations
Percutaneous Transcatheter Implantation of an Aortic Valve Prosthesis for Calcific Aortic Stenosis
Alain Cribier, Hélène Eltchaninoff, Assaf Bash et al. · Circulation · 2002 · 3.2K citations · Full text
Medicine, Cardiology, Surgery +16