EducationKinesiologyPhysical MedicineBiomechanicsMovement AnalysisOrthopedic BiomechanicsBiomechanics Of Athletic MovementFoot BiomechanicsFootwear DesignGait AnalysisGait AssessmentGait BiomechanicsAccelerometer SensorsBiomechanical Evaluation Of FootwearFootwear BiomechanicsGaitHeel Strike Mechanics
Spectral analysis methods have been used to examine the influence of shock absorbing inserts on heel strike transients in normal gait. The data were obtained from a piezoelectric accelerometer mounted on a custom moulded splint fitting around the malleoli which was found to eliminate unwanted resonances. The peak accelerations measured with this system were similar to those obtained in earlier studies. Examination of the gait of one subject in four different types of footwear showed that a reduction of rms acceleration could be achieved by the use of a shock absorbing insert. The efficiency of the insert was measured by its ability to reduce the rms acceleration in the 10–150 Hz band and to reduce the rms signal in the 50–150 Hz band as a proportion of the total. This second measure was defined as the ‘Shock Factor’.
5
Response of joints to impact loading — III
Eric L. Radin, Howard G. Parker, James Pugh et al. · Journal of Biomechanics · 1973 · 618 citations
Peak dynamic force in human gait
Sheldon R. Simon, Igor L. Paul, Joseph M. Mansour et al. · Journal of Biomechanics · 1981 · 271 citations
Education, Physiology, Biomechanics +13