International Journal of the Physical Sciences · 2010 · 47 citations · 18 references
EngineeringAerospace EngineeringChemical EngineeringAerodynamicsFlow AssuranceFluid DynamicsAerodynamic TestingCyclone SeparationExperimental AerodynamicsPressure Drop PredictionVortex DynamicsCritical DiameterCyclone Separator DesignCyclone Separator PerformancePressure DropPressure Drop MeasurementPressure Loss CalculationsPressure-drop ModelingVortex Finder Design
In this study, three cylinder-shaped vortex finders with diameters of 80, 120 and 160 mm were designed and manufactured to find out the pressure drop of the cyclones by experimentally investigating the effects of gas inlet velocity, the vortex finder diameter and length on the cyclone performance at different gas concentration. As a result of this experimental analysis, a critical diameter of vortex finder is obtained as 120 mm. Furthermore, analyzing the experimental findings with a statistical regression method indicated that there was a linear relationship between length of vortex finder and pressure loss. Then, according to the analysis results, relevance values were obtained as 98.87, 98.37 and 97.59% for these vortex finders (with diameters of 80, 120 and 160 mm), respectively. Key words: Cyclone, vortex finder, pressure drop.