INTRAOCULAR PRESSURE IN CAPTIVE AMERICAN FLAMINGOS (<i>PHOENICOPTERUS RUBER</i>) AS MEASURED BY REBOUND TONOMETRY

24

Citations

12

References

2014

Year

Abstract

Intraocular pressure was measured using rebound tonometry in American flamingos (Phoenicopterus ruber), with the head in an upright standing position and when lowered in a feeding position, to establish a reference range. Mean +/- standard deviation (SD) (range) intraocular pressure for flamingos with the head in an upright position was right eye (OD)= 10.9 +/- 1.8 mm Hg (7-15 mm Hg) and left eye (OS) = 11.1 +/- 2.3 mm Hg (8-21 mm Hg). Median intraocular pressure for flamingos with the head in an upright position was OD and OS = 11 mm Hg. Mean intraocular pressure for flamingos with the head in a feeding position was OD = 14.3 +/- 2.5 mm Hg (10-22 mm Hg) and OS = 14.4 +/- 2.7 mm Hg (11-24 mm Hg), which were significantly higher. Median intraocular pressure for flamingos with the head in a feeding position was OD and OS = 14 mm Hg.