Concepedia

Publication | Closed Access

Control method for Inductive Power Transfer with high partial-load efficiency and resonance tracking

80

Citations

19

References

2014

Year

Abstract

Frequency controlled Inductive Power Transfer (IPT) systems for Electric Vehicle (EV) battery charging applications often suffer from high power losses in partial-load, because the transmitter coil current is not significantly reduced at low output power. Therefore, in this paper a novel control method is presented that exhibits a substantially higher partial-load efficiency, while it also enables full control of the power semiconductor switching conditions. The power flow control is based on the dynamic regulation of the dc-link voltages on both sides of the resonant system with dc-dc-converters. Additionally, a tracking of the resonance with a current zero crossing detection circuit and a PLL makes the switched current an additional degree of freedom, that can be used, e.g., for the minimization of IGBT soft-switching losses due to stored-charge. All calculated results are supported by experimental measurements on an existing 5 kW/52mm air gap/210mm coil diameter prototype system with an efficiency of more than 96.5% at maximum power and above 96% down to 20% rated power.

References

YearCitations

Page 1