Natural SciencesBiophysicsMaterials ScienceElectromagnetismMagnetic MaterialsMagnetic Resonance BiophysicsMagnetic CharacterizationMagnetic Resonance Contrast MechanismsMagnetic Resonance ImagingMagnetic Resonance Imaging PhysicsMagnetic SusceptibilityMagnetization ProcessesIonizing IrradiationIrradiation EffectsMagnetic Property CharacterizationMagnetic Relaxation MeasurementsMagnetic Saturation EffectsMagnetization MeasurementOff-resonance ContrastOff-resonance Effects
Magnetization transfer contrast (MTC) experiments using off-resonance irradiation have been performed with an agar gel model by systematically varying offset frequency, amplitude of the RF irradiation and gel concentration. The experimental results are shown to be quantitatively modelled by a two-pool system consisting of a liquid pool with a Lorentzian line shape and a small semisolid pool with a Gaussian lineshape. The fitted model yields physically realistic fundamental parameters with a T2 of the semisolid pool of 13 microseconds. Further analysis shows that the off-resonance irradiation MTC experiment had significant limitations in its ability to saturate the semisolid pool without directly affecting the liquid component.
27