Journal of Structural Engineering · 1995 · 114 citations · 3 references
EngineeringCivil EngineeringMaterials EngineeringBuilding MaterialsBuilding StructuresStructural EngineeringConcrete TechnologyFire ModelingFire-resistant MaterialsReinforced Concrete StructuresSteel ConstructionStructural Fire EngineeringColumn GeometryColumnsFire ResistanceFire Resistance AssessmentReinforced ConcreteStructural Fire Response AnalysisStructural Fire Response Modeling
Experimental and theoretical studies have been carried out to predict the fire resistance of rectangular hollow steel columns filled with bar-reinforced concrete. A mathematical model to calculate the temperatures, deformations, and fire resistance of the columns is presented in this paper. Calculated results are compared with those measured. The results indicate that the model is capable of predicting the fire resistance of square hollow steel columns, filled with bar-reinforced concrete, with an accuracy that is adequate for practical purposes. The model enables the expansion of data on the fire resistance of square concrete-filled steel columns, which at present consists predominantly of data for columns filled with plain concrete with data for columns filled with bar-reinforced concrete. Using the model, the fire resistance of square concrete-filled steel columns can be evaluated for any value of the significant parameters such as load, column-section dimensions, column length, and the percentage of reinforcing steel, without the necessity of testing.
3
FIRE RESISTANCE OF REINFORCED CONCRETE COLUMNS
T. D. Lin, R I Zwiers, R G Burg et al. · NPARC · 1992 · 54 citations