Journal of Hygiene · 1952 · 25 citations · 4 references
EngineeringInfectious DiseasesMicrobiologyAerodynamicsMedical MicrobiologyVentilationAerosol ScienceAirflow DistributionSpraying EquipmentWind-tunnel TestingAirborne PathogensBiological AerosolsMicrobial AerosolizationMicrobial Dispersion In Air
A vertical closed circuit wind tunnel is described in which a spinning top sprayer is used as a source of homogeneous particles of pathogenic organisms. The dry particle size may be set at any figure between 1 and 20 µ, and the cloud concentration can be varied over wide limits. Provision is made for humidity control. Animals may be exposed to the cloud, and samples taken from it. The apparatus can be sterilized with flowing steam and formalin. An appendix giving details of the operational technique is available on request.
4
An apparatus for the study of airborne infection
D. W. Henderson · Journal of Hygiene · 1952 · 214 citations · Full text
An Improved Spinning Top Homogeneous Spray Apparatus
K. R. May · Journal of Applied Physics · 1949 · 144 citations