EngineeringElectrical EngineeringMechanical EngineeringElectric MachinesHydraulic EngineeringHydraulicsElectrical System TestingGenerator OperationHydraulic MachineryHydraulic MachinesHydropower EngineeringHydropower SystemsFrequency Response TestingFrequency-domain TestingGeneratorsGovernor SystemsMechanical PerformanceMotor Performance TestingMotor TestingVariable Speed Operation
The Bureau of Reclamation has developed new equipment and procedures for testing mechanical-hydraulic governors for hydroelectric generators. The test equipment generates a three-phase voltage that will drive the governor ballhead motor at variable speed. Most traditional governor tests can be completed with the generating unit unwatered using this equipment. In addition, frequency response testing and other detailed analytical tests can be performed to validate governor models using this equipment.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>