Classical and Quantum Gravity · 2006 · 23 citations · 13 references
Natural SciencesElectrical EngineeringPhysicsInstrumentationOptical AstronomyOpticsInterferometryOptical InstrumentationDetectorsOptical AlignmentOptical InterferometersSignalsStrong CouplingStrong Coupling EffectsWave Sensors
The automatic alignment system of the Virgo interferometer differs substantially from those used in similar experiments, since it uses a variant of the Anderson technique. This implies a completely different control topology with respect to other detectors, and the main feature is a strong coupling of different degrees of freedom in the optical signals. It also provides two extra output ports in which differential wave-front sensors can be placed, namely the light transmitted by the Fabry-Perot arm cavities. We report on the first experimental demonstration of this technique on a large scale recycled interferometer, and on the present status of the automatic alignment system.
13
Automatic alignment of optical interferometers
E. Morrison, B. J. Meers, D. I. Robertson et al. · Applied Optics · 1994 · 271 citations
F. Acernese, M Alshourbagy, P Amico et al. · Classical and Quantum Gravity · 2008 · 211 citations · Full text
Alignment of resonant optical cavities
Dana Z. Anderson · Applied Optics · 1984 · 191 citations
Natural Sciences, Physics, Optics +11
Experimental demonstration of an automatic alignment system for optical interferometers
E. Morrison, B. J. Meers, D. I. Robertson et al. · Applied Optics · 1994 · 132 citations