Gross hematuria: a complication of intrapelvic cement intrusion in total hip replacement

Adam Greenspan, A. Norman

American Journal of Roentgenology · 1978 · 27 citations · 12 references

Concepts

Abstract

Four patients with gross hematuria and dysuria following intrusion of methylmethacrylate into the pelvic cavity after total hip replacement are described. This is a rare, benign complication which generally occurs 7-14 days after surgery and subsides promptly with symptomatic treatment. The diagnosis can be made on a simple radiography of the pelvis which shows the radiopaque cement as a mass intruding with the pelvic cavity. On the urogram it frequently abuts against or produces an extrinsic impression on the urinary bladder. This complication is very likely a result of the exothermal reaction during polymerization of the methylmethacrylate.

References